Great Plains Industries / GPI G2 Industrial Grade, Flow Meters, Threaded, Brass, ATEX Approved
Superb quality turbine meters, for use with any thin viscosity liquids which are not chemically agressive to the materials from which the components are made
Displays Flowrate, 2 Resettable Totals, and 1 Non-Resettable Cumulative Total
Optional Lexan Cover helps to protect from accidental damage
Approvals
- USA;FM - Intrinsically safe for class I,II,III Division 1, Group ABCDEFG. Non-incendive for class I,II,III, Division 2, Group ADCDFG
- European;Atex II 1 G Ex ia IIC T6 Ta
Full Options ChartG2 | | | | | | | Grade | G2 |
| B | | | | | | Turbine Body Material | Brass |
| | 05 | | | | | Nominal Bore | 1/2" |
| | 07 | | | | | Nominal Bore | 3/4" |
| | 10 | | | | | Nominal Bore | 1" |
| | 15 | | | | | Nominal Bore | 1.5" |
| | 20 | | | | | Nominal Bore | 2" |
| | | N | | | | Fitting Type | NPT Female |
| | | I | | | | Fitting Type | ISO7 / BSP Female Taper |
| | | | 09 | | | Electronics | Turbine with local display = 2 Button Computer, Field Configurable (Cumulative, Batch & Rate) |
| | | | 19 | | | Electronics | Turbine with local display = Vertical Mount 2 Button Computer, Field Configurable (Cumulative, Batch & Rate) |
| | | | 41 | | | Electronics | Remote Pulse-Out Transmitter & Sine Wave Pickup (Standard Remote Sensor Option) |
| | | | 43 | | | Electronics | Remote Pulse-Out Transmitter & Turbine Mounted Computer (Pulse Out Sensor Option) |
| | | | 51 | | | Electronics | GG500 Remote Standard Display with Sine Wave Pickup (Standard Remote Sensor Option) |
| | | | 52 | | | Electronics | GG500 Remote Standard Display with Open Collector Pickup (Conditioned Signal Sensor Option) |
| | | | 53 | | | Electronics | GG500 Remote Standard Display with Turbine Mounted Computer (Pulse Access Sensor Option) |
| | | | 61 | | | Electronics | GX500 Remote 4-20Ma Transmitter with Display with Sine Wave Pickup (Standard Remote Sensor Option) |
| | | | 62 | | | Electronics | GX500 Remote 4-20Ma Transmitter with Display with Open Collector Pickup (Conditioned Signal Sensor Option) |
| | | | 63 | | | Electronics | GX500 Remote 4-20Ma Transmitter with Display with Turbine Mounted Computer (Pulse Access Sensor Option) |
| | | | 71 | | | Electronics | GA500 Remote 4-20Ma Transmitter with Sine Wave Pickup (Standard Remote Sensor Option) |
| | | | 72 | | | Electronics | GA500 Remote 4-20Ma Transmitter with Open Collector Pickup (Conditioned Signal Sensor Option) |
| | | | 73 | | | Electronics | GA500 Remote 4-20Ma Transmitter with Turbine Mounted Computer (Pulse Access Sensor Option) |
| | | | XX | | | Electronics | None - Turbine Only |
| | | | | GM | | Calibration | US Gallons / Min |
| | | | | LM | | Calibration | Litres / Min |
| | | | | XX | | Calibration | None (Use with electronics choices 41, 71, 72 or Turbine Only) |
| | | | | | A | Retail Box | For Turbine Only or Turbine with Mounted Local Display (NB 05-10) |
| | | | | | B | Retail Box | For Turbine Only or Turbine with Mounted Local Display (NB 15-20) |
| | | | | | C | Retail Box | For Turbine with Remote Transmitter (with or without Turbine Mounted Local Display (NB 15-20) |
| | | | | | D | Retail Box | 19 Electronics Choice: B Packaging Designation (Size 05-10), or C Packaging Designation (Sizes 15-20) |
Models Available & PerformanceG2B05 | 1/2" BSP | 3.8 to 38 lpm Flow Rate | Accuracy ±2.0% |
G2B07 | 3/4" BSP | 7.6 to 76 lpm Flow Rate | Accuracy ±1.5% |
G2B10 | 1" BSP | 19 to 190 lpm Flow Rate | Accuracy ±1.5% |
G2B15 | 1.5" BSP | 38 to 380 lpm Flow Rate | Accuracy ±1.0% |
G2B20 | 2" BSP | 76 to 760 lpm Flow Rate | Accuracy ±1.0% |
Features & PerformanceDisplay | Digital |
Power Source | 2x Special Lithium Batteries |
Factory Calibration | Yes |
User Calibration | Yes |
Temperature Range | -10 to +60 Celcius |
Maximum Pressure | 21 Bar / 304.5 PSI |
Maximum Viscosity | 100 Centipoises |
Wetted ComponentsHousing | Brass |
Journal Bearings | Ceramic |
Shaft | Tungsten Carbide |
Rotor | PVDF (Kynar) |
Rings | 316 Stainless Steel |
Signal Generators | (Ferrite) Ceramic Magnet |
G2 SERIES TURBINE METER SIGNAL MODULES

4-20mA Module
125100-1
Combine the 4-20mA module with a G2 meter and 09 electronics to provide an industry standard analog signal for connection to a wide variety of chart recorders, display equipment, and process control equipment

Conditioned Signal Output Module
113435-1
Combine the Conditioned signal Output Module with a GPI Turnine Kit to create a low cost flow sensor with digital signal output which interfaces with various counters, controllers, and compatible process equipment. Comes with 10ft Cable.

GPI Electronics Programmer
113800-06
Includes Software CD, Electronics programming board, cable and complete installation guide

External Power Module
125070-1
Combining the External Power Module with the Pulse Access Module, and Turbine meter allows the use of an external power source (7 to 35 vDC) that supplies power to the computer electronics. Requires Pulse Access Module 1250600-1

FM Approved Remote Assembly
11327501
The Factory Mutual (FM) Approved Remote Assembly modifies all GPI Electronic Digital Meters for applications in specialised situations including remote indication and high or low fluid metering applications. Comes with 10ft Cable

FM Approved Sensor
120077-1
Designed for use with G2 meters when pulse output is required and the meter is located within a hazardous location. Includes sensor, screws, cover plate, and jam nut. Connection Kit 113524-01 is sold separately

Pulse Access Module
125060-1
Combine the Pulse Access Module with a G2 meter and 09 electronics to create a low cost flow sensor with local readout and pulse output which interfaces with counters, controllers, and compatible process equipment. Comes with 10ft Cable


Local 4-20mA Transmitter
GA500 & GA510
Loop powered 4-20mA output without display. Lockout feature prevents tampering. Remote (GA500) or Local (GA510) mounting


Display with Pulse Output
GG500-M (Remote, Units/Minute), GG500-H (Remote, Units/Hour), GG510-M (Local, Units/Minute), GG510-H (Local, Units/Hour)
Battery powered rate and total display with an external power option - pulse output. Flowrate in units per hour or per minute.


Display with 4-20mA Transmitter
GX500-M (Remote, Units/Minute), GX500-H (Remote, Units/Hour), GX510-M (Local, Units/Minute), GX510-H (Local, Units/Hour)
Loop powered 4-20mA output with rate and total display. Lockout feature prevents tampering. Flowrate in units per hour or per minute

RS232 / RS485 Module
125300-10
Combine the RS232 / RS485 Module with a G2 meter and 09 electronics to provide an RS232 or RS485 output to a PC, laptop or other device


Scaled Pulse Module
SC500 (Remote), SC510 (Local)
Selectable K-Factor converts input frequency to scaled pulse output. SC500 includes the mounting bracket and 20ft Cable, SC510 includes a 1”FNPT folded connection for direct mounting to a meter. NEMA 4

Display Adaptor Kit
125260-01
90 Degree Display Adaptor Kit allows for horizontal readout of vertical meters, includes adaptor, o’ring, screws and foam spacers required for installation
510 Conversion Kit
113440-01
This kit combines the conduit adaptor (113437-01) with a sensor to allow easy installation of the 510 series displays to a G2 meter sold separately

Pulse Access dust Cover
125080-01
Used with the Remote Kit, this part replaced the dust cover that houses the electronic display. This module allows the signal in from the turbine and a square wave open collector output signal from 0-60vDC

Conduit Adaptor
113437-01
The Conduit Adaptor allows you to enclose wiring from the magnetic pickup. The kit includes a turbine meter cover with a 1” NPT conduit fitting and screws for plastic or meter meter body installation

Connector Kit for FM Approved Sensor
113524-01
Includes MS3106-10SL-3S and cable clamp (cable sold separately)
Remote Cable Kit
113272-500
100ft / 30m cable for standard and FM Remote Kits, 2 wire. Belden #9501 shielded
Output Cable Kit
125066-500
100ft / 30m cable for Conditioned Signal Output 4-20mA Module and Pulse Access Module, 3 Wire. Belden #9363 Shielded
Twin Lithium Battery Kit
113520-1
Replacement battery kit for G2 Series Meters
Protective Lexan Cover for G2 Series Meters
906004-86
Protective Lexan Cover for G2 series meter electronic displays, simply snaps on over the electronics and buttons can be pressed through the protective cover
SPECIAL ORDER ITEM - If urgent please email before purchasing
Download GPI Industrial Grade, ATEX Approved Flow Meters Brass, Spec PDF
Download GPI Industrial Grade, ATEX Approved Flow Meters Brass, Liquid Viscosities PDF
Download GPI Industrial Grade, ATEX Approved Flow Meters Brass, Manaul PDF
Download GPI Industrial Grade, ATEX Approved Flow Meters Brass, Chemical Compatibility Guide PDF
Download GPI Industrial Grade, ATEX Approved Flow Meters Brass, Build Your Own G2 Meter PDF
Download GPI Commercial Grade, ATEX Certificate PDF