UK Freight only 8.75
Protego DR-UN In-Line Detonation Flame Arrester, Endurance Burning Proof, ATEX
  • Click to enlarge

Protego DR-UN In-Line Detonation Flame Arrester, Endurance Burning Proof, ATEX

For Stable Detonations And Deflagrations In Right Angle Design With Shock Absorber, Unidirectional

DR-UN Explosion Group: IIA1, D / IIA, C / IIB1, C / IIB2, C / IIB3

  • Same dimensions as the PROTEGO DR/U, therefore replacement possible without converting the piping
  • The suspended FLAMEFILTER cage (4) enables quick removal and installation of the complete PROTEGO flame arrester unit and then replacing the individual FLAMEFILTER
  • Modular design and optimum availability of spare parts guarantee fast maintenance
  • Only three FLAMEFILTER discs due to shock absorber technology
  • Low pressure loss results in low operating and lifecycle costs
  • Cost efficient spare parts

Function and Description

The PROTEGO DR-UN in-line detonation flame arrester are used to secure potentially explosive plants against pipe deflagrations and stable detonations. In the right-angle design and with the PROTEGO® DR/U identical dimensions, the PROTEGO DR-UN offers considerable maintenance and cost benefits.

Once a detonation enters the device, energy is absorbed from the detonation shock wave by the integrated shock absorber (1) before the flame is extinguished in the narrow gaps of the FLAMEFILTER® (3).

The PROTEGO® flame arrester unit (2) consists of several FLAMEFILTER discs and spacers firmly held in the FLAMEFILTER cage (4). The gap size and number of FLAMEFILTER discs are determined by the operating data of the mixture flowing in the line (explosion group, pressure, temperature). This device is approved for explosion groups from IIA to IIB3 (NEC group D to C MESG ≥ 0.65 mm).

The standard design is approved at an operating temperature up to +60°C / 140°F and an absolute operating pressure up to 1.2 bar / 17.4 psi.

EU conformity according to the currently valid ATEX directive.

Dimensions
DN25 / 1"32 / 1 1/4"40 / 1 1/2"50 / 2"65 / 2 1/2"80 / 3"100 / 4"150 / 6"200 / 8"
a100 / 3.94125 / 4.92140 / 5.51150 / 5.91160 / 6.30185 / 7.28250 / 9.84300 / 11.81350 / 13.78
b125 / 4.92150 / 5.91160 / 6.30165 / 6.49185 / 7.28195 / 7.68250 / 9.84300 / 11.81350 / 13.78
c189 / 7.44214 / 8.43259 / 10.2264 / 10.39307 / 12.09317 / 12.08374 / 14.72464 / 18.27707 / 27.83
c1280 / 11.02310 / 12.20370 / 14.57375 / 14.76485 / 19.09495 / 19.09585 / 23.03705 / 27.751170 / 46.06
d149 / 5.87149 / 5.87210 / 8.27210 / 8.27275 / 10.83275 / 10.83325 / 12.80460 / 18.11620 / 24.41
e----326 / 12.83336 / 13.23403 / 15.87475 / 18.70707 / 27.83
xy475 / 18.70500 / 19.69570 / 22.44580 / 22.83690 / 27.17700 / 27.56770 / 30.31905 / 35.631305 / 51.38

To select the nominal width/nominal size (NG/DN) - combination, use the flow capacity charts. *Dimensions in mm / inches.

Material Selection For Housing
DesignBC
HousingSteelStainless Steel
Cover with shock absorberSteelStainless Steel
O'RingFPMPTFE
Flame arrester unitABC, D
Material Combinations Of Flame Arrester Unit
DesignACD
FLAMEFILTER cageSteelStainless SteelStainless Steel
FLAMEFILTERStainless SteelStainless SteelHastelloy
SpacerStainless SteelStainless SteelHastelloy

Other FLAMEFILTER materials upon request. Special materials upon request.

Selection Of The Explosion Group
MESGExpl. Gr. (IEC/CEN)Gas Group (NEC)

Special Approvals Upon Request

> 0.90 mmIIAD
≥ 0.65 mmIIB3C
Selection Of Max Operating Pressure
Expl. GrDN25 / 1"32 / 1 1/4"40 / 1 1/2"50 / 2"65 / 2 1/2"80 / 3"100 / 4"150 / 6"200 / 8"
IIA Pmax---2.0 / 29.02.0 / 29.02.0 / 29.02.0 / 29.01.2 / 17.41.6 / 23.2
IIB3 Pmax1.4 / 20.31.4 / 20.31.4 / 20.31.4 / 20.31.2 / 17.41.2 / 17.41.2 / 17.41.2 / 17.41.1 / 15.9

Pmax = maximum allowable operating pressure in bar / psi (absolute).

Specification Of Max Operating Temperature
≤ 60 °C/ 140 °FT maximum allowable operating temperature in °C
Flange Connection Type
EN 1092-1; Form B1
ASME B16.5 CL R.F
Design Types And Specifications
DR-UNBasic design of the detonation flame arrester.
DR-UN-TIn-line detonation flame arrester with integrated temperature sensor* as additional protection against short time burning.

*Resistance thermometer for device group II, category (1) 2 (GII cat. (1) 2).

Product Options

£0.00

Email us for availability

Product CodeProtego_DR-UN
ConditionNew

This field is required.
Top