Parker Velcon, ACOX Series Aviation Fuel Filter Monitor Cartridges
With our barrier technology, current filtration equipment at FBO and fixed fuelling sites with lower flow rate systems can easily adapt this alternative solution. Parker Velcon SAP-free barrier filtration provides a drop-in replacement for our monitor cartridges used in models VF-61 (5”) and VF-609 (6”) housings and similar competitors housings.
Our new surface/barrier filter element is manufactured using a very fine hydrophobic material that prevents solids and water from passing through. There is absolutely no SAP used in this filter. Solids are held within the element while water is repelled by the hydrophobic material and falls to the bottom of the vessel.
With our ACOX element range, there is no need for expensive & costly retrofitting of filtration systems for smaller into-plane fuelling applications. ACOX filter elements are a true direct drop-in replacement for the various filter housings.
Replace the cartridge when the differential pressure reaches 22 PSID or after one year of service. Because of the limited sump space in the vessel, IT IS IMPERATIVE to drain the sump at EVERY FUELLING. As an option, a water detection probe is available for installation, Parker Velcon part number 125-Q.
- Water and dirt are prevented from passing downstream allowing only clean, dry fuel.
- Drop in solution for existing housings without the need for costly retrofitting or addition of
- electronic sensors.
- No SAP materials used in the manufacture of ACOX series of elements.
- Effective against low-water emulsions and water 'slugs'.
- Effective in fuel containing FSII (anti-icing additive).
- Pressure increase signals need for cartridge change, replace when the differential pressure reaches 22 PSID
- Meets the effluent fuel quality and structural requirements of EI-1588.
- Minimal changes to your current operational procedures
- No modifications to the filter housing, use with existing filter housings
- Outside-to-inside flow pattern
- Suitable for Jet-A1 & AvGas
- Can be used with fuels that are pre-mixed with Anti-Icing Additives (FSII)
Current Production is Suffix 'B'.
ACO Cartridge Selection Table| Model Number | Micron Rating | Inside Dia. (in.) | Outside Dia. (in.) | Length (in.) | Collapse Pressure (PSI) | Max. Flow Rate (US GPM) | Max. Op. Temp. | Interchange Information |
| ACOX-512A | TBC @ Nom. TBC% Efficiency | 1,7/8 | 5,5/8 (5.625) | 12,1/4 | TBC | 48 | TBC | Fits VF-61 Housing |
| ACOX-524A | TBC @ Nom. TBC% Efficiency | (1.875) | (5.625) | (24.25) | TBC | 96 | TBC | |
| ACOX-609A | TBC @ Nom. TBC% Efficiency | 1,1/2 | 6 | 9,11/16 | TBC | 36 | TBC | Fits Fram/Facet VFCS-21 (Element CC-21-7); VF-609 |
| ACOX-612A | TBC @ Nom. TBC% Efficiency | 1,1/2 | 6 | 13,3/4 | TBC | 48 | TBC | Fits Fram/Facet VFCS-22 (Element CC-22-7) |
| ACOX-614A | TBC @ Nom. TBC% Efficiency | 3,1/2 | 6 | 14,1/2 | TBC | 56 | TBC | |