UK Freight only 8.75
Aquametro, CONTOIL VZF II MI005 (OIML R117) Conformity, Electronic Oil Flow Meters, PN25 Or PN40 Flanged
  • Click to enlarge

Aquametro, CONTOIL VZF II MI005 (OIML R117) Conformity, Electronic Oil Flow Meters, PN25 Or PN40 Flanged

ALWAYS EMAIL US FOR BEST PRICES ON AQUA METRO!

Oil meters with mechanical roller counter, and with DIN 2501 (As Standard) flanged connections.

American ANSI 150 and Japanese JIS 10-20K flange drillings are available at no extra cost, these are not added to the part number charts below because they have no factory defined part numbers, however for weights and dimensions, please use standard DIN 2501 listed specifications.

Electronic counter with display of total volume, subtotal volume (can be reset) in m3, litres or US gallons. Flow rate per minute or hour and operation hours. Transmitter with 2 configurable signal outputs for volumetric pulses, flow rate (current or frequency) or limit switch

VZF 'II' are the new models for 2017 which include temperature compensation for more accurate metering.

  • MI005 (OIML R117) Conformity for resale use

Suitable for Fuel Types;

  • Heating Fuel, Extra Light / Light / Medium / Heavy (DN20 or above)
  • Kerosene
  • Naphtha
  • Diesel
  • Petrol
  • Lubricating Oils

Your Benefits

  • Reliable monitoring and flexible control of the system without additional transducers
  • Simplifying burner settings for optimum performance
  • Simple commissioning, maintenance-free
  • Space saving installation without requirement for straight inlet or outlet paths
  • Easy to install without restriction either horizontally or vertically
  • Maximum safety due to integral particle filter in meter inlet

Meters for heavy fuel oil should have a nominal diameter of DN 20 or larger

IMPORTANT - All meters must be fitted with a pre-filter of 100 Microns, Maximum. Ingress of particles over 100 microns may lead to wear and or jamming of the Rotary Piston, and will not be covered by Warranty

Specification
 VZF II 15VZF II 20VZF II 25VZF II 40VZF II 50
Nominal Diameter15 mm / 1/2"20 mm / 3/4"25 mm / 1"40 mm / 1.5"50 mm / 2"
Installation Length165 mm165 mm190 mm300 mm350 mm
Connection ThreadsNone, DIN 2501 FlangedNone, DIN 2501 FlangedNone, DIN 2501 FlangedNone, DIN 2501 FlangedNone, DIN 2501 Flanged
Nominal Pressure - Threaded16 Bar16 Bar16 Bar16 Bar16 Bar
Nominal Pressure - Flanged25 Bar or 40 Bar25 Bar or 40 Bar25 Bar or 40 Bar25 Bar or 40 Bar25 Bar or 40 Bar
Maximum Temperature+130 or +180 Celcius+130 or +180 Celcius+130 or +180 Celcius+130 or +180 Celcius+130 or +180 Celcius
Maximum Flow Rate600 lph1,500 lph3,000 lph9,000 lph30,000 lph
Continuous Flow Rate400 lph1,000 lph2,000 lph6,000 lph20,000 lph
Minimum Flow Rate10 lph30 lph75 lph225 lph750 lph
Approx Starting Flowrate4 lph12 lph30 lph90 lph300 lph
Maximum Permissible Error±0.3% of reading±0.3% of reading±0.3% of reading±0.3% of reading±0.3% of reading
Smallest Readable Amount0.1 Litre0.1 Litre0.1 Litre0.1 Litre0.1 Litre
Registration Capacity10,000,000 Litres10,000,000 Litres10,000,000 Litres10,000,000 Litres10,000,000 Litres
Flow Rate Display1 Decimal Place1 Decimal Place1 Decimal Place1 Decimal Place1 Decimal Place
Safety Filter Mesh Size400 Micron400 Micron400 Micron800 Micron800 Micron
Dirt Filter Mesh Size250 Micron400 Micron400 Micron600 Micron600 Micron
Volume of Measuring Chamber12 cm336 cm3100 cm3330 cm31,200 cm3
Ingress ProtectionIP65IP65IP65IP65IP65
Dimensions & Weight
 VZF II 15VZF II 20VZF II 25VZF II 40VZF II 50
Length165 mm165 mm190 mm300 mm350 mm
Width105 mm105 mm130 mm210 mm280 mm
Height155 mm164 mm191 mm243 mm299 mm
Weight - PN25 Flanged3.8 kg4.5 kg7.5 kg20.3 kg41.0 kg
Weight - PN40 Flanged4.4 kg5.5 kg7.8 kg20.5 kg42.0 kg
Aqua Metro Model Numbers
DisplayTemp MaxPressure MaxPulser TypeLitres Per PulsePulses Per LitrePart Number DN15Part Number DN20Part Number DN25Part Number DN40Part Number DN50
Local, Digital130 Celcius25 Bar---VZF II 15 FL 130/25 CEVZF II 20 FL 130/25 CEVZF II 25 FL 130/25 CEVZF II 40 FL 130/25 CEVZF II 50 FL 130/25 CE
Local, Digital180 Celcius25 Bar--------
Local, Digital180 Celcius40 Bar--------Aqua Metro Part Numbers
DisplayTemp MaxPressure MaxPulser TypeLitres Per PulsePulses Per LitrePart Number DN15Part Number DN20Part Number DN25Part Number DN40Part Number DN50
Local, Digital130 Celcius25 Bar---9557595575955769557795578
Local, Digital180 Celcius25 Bar--------
Local, Digital180 Celcius40 Bar--------

Download Aqua Metro, VZF Electronic Oil Flow Meters PDFDownload Aqua Metro, VZF Electronic Oil Flow Meters PDF

Download Aqua Metro, VZF II Electronic Oil Flow Meters PDFDownload Aqua Metro, VZF II Electronic Oil Flow Meters PDF

Download Aqua Metro Flange Drilling Options PDFDownload Aqua Metro Flange Drilling Options PDF

Download Aqua Metro VZF II & VZF/A II Mounting & Operating Instructions PDFDownload Aqua Metro VZF II & VZF/A II Mounting & Operating Instructions PDF

Download Aqua Metro /CE MI005 Meters - Declaration of Conformity PDFDownload Aqua Metro /CE MI005 Meters - Declaration of Conformity PDF

Product Options

£1,782.00


Product CodeAQU11IIC58
ConditionNew

This field is required.
Top
This item has been added to your cart...