GMP, Self Priming Centrifugal Pump, High Capacity, B6XR-A, for Semi-Trash / Sewage
Self-priming electric pump made in bare shaft version with joint. Particularly suitable for use with dirty water containing sand, mud and solid bodies (up to a maximum of 70 mm). Suitable for the construction and emergency sectors for rapid emptying. Pumps equipped with inspection hatch for rapid cleaning of the impeller.
NOT SUITABLE for Gasoline/Petrol - use GMP, RED, ATEX Approved, Self-Priming Centrifugal Pumps for Petrol, Bronze
Wetted Components| Pump Body | Cast Iron |
| Impeller Case | Cast Iron |
| Impeller Case Seal | NBR |
| Motor Shaft Seal | NBR |
| Vanes | Not Present |
| Vane Springs | Not Present |
| Rotor / Gear / Impellor / Grinder | Cast Iron |
| Shaft Key / Nut | Not Present |
| Motor Shaft | Stainless Steel |
| Bypass Valve Piston | Not Present |
| Bypass Valve Spring | Not Present |
Performance| Voltage / Frequency | 400/690vAC 3Ph 50Hz |
| kW | 11, See Table Below |
| Amps | |
| RPM | 2900 |
| Duty Cycle | Continuous |
| Cable Length | None |
| Bypass Valve Y/N | N |
| Max Flow | 4300 lpm, See Table Below |
| Discharge Pressure | 1.42 Bar, See Table Below |
| Max Suction Lift (Dry) | TBC |
| Max Suction Lift (Wet) | TBC |
| Inlet Fitting | Various, See Table Below |
| Outlet Fitting | Various, See Table Below |
| Max Particle Tolerance | TBC |
| Max Liquid Temp | +40 C |
| Min Liquid Temp | |
| Max Room Temp | |
| Min Room Temp | |
| Thermal Protection Y/N | Y |
| Ingress Protection | TBC |
Options Available| GMP Cat No | Pump Model No | kW | Motor | DNM | Weight (Kg) | Dimensions (L*W*H) | H max (m) | Q max (l/ min) |
| EAVM | B6XR-A(*50mm) | 11 | 400/ 690 T | DN 150 / DN 150 | 360 | 550*1300*680 | 14.2 | 4300 |